7-4

ADS FlowShark Manual

Mounting the Monitor to the Manhole
Wall

Mount the monitor to the manhole wall using the monitor bracket as
follows:

1. Determine the appropriate location to mount the monitor

bracket to the manhole wall. Consider the following when
selecting the proper location:

 Select a location that will allow you to remove the monitor

easily during service visits using the mounting bracket
(extension handle).

 Select a location that provides only a minimal potential for

the monitor to experience surcharge conditions.

 Select a location that will prevent the manhole lid from

potentially damaging the monitor during removal or when
rotating in the opening.

 Select a location that will allow personnel to enter/exit the

manhole without removing the monitor.

2. Hold the top end of the mounting bracket against the manhole

wall, and mark the location for the mounting hole through the
keyhole in the bracket.

3. Drill a hole 2½ inches deep at the mark, and install a 3/8-inch x

3-inch anchor bolt in the hole.

Note: Make sure all anchor bolts, studs, nuts, and
washers used in mounting the monitor are stainless steel.

4. Twist a nut onto the anchor bolt, but do not tighten it down.

Leave enough space between the nut and the wall for the
thickness of the mounting bracket.

5. Mount the bottom of the bracket onto the monitor flange with

two 3/8-inch x 1-inch hex bolts, 3/8 – 16 hex nuts, and 3/8-inch
washers.

Advertising