Sensor Installation and Connection 3-29

Mounting the Ultrasonic Depth Sensor

Two special installation methods are available for mounting the
ultrasonic depth sensor:

Standard Ultrasonic Mount This option, the most common
method employed today, is used for mounting the ultrasonic
depth sensor in the pipe during special installations.

Surcharge Mount This mount primarily is used for
mounting the ultrasonic depth sensor in the manhole at a site
where the flow continually occurs within 2 inches of the top of
the pipe or sites where a pressure sensor is not available and
surcharges frequently occur. Surcharges are conditions where
the flow completely fills the pipe and extends up into the
manhole.

Standard Ultrasonic Mount

Mount the ultrasonic depth sensor using this method in the
following way:

Note: Handle the ultrasonic depth sensor with care, and
do not expose it to extreme temperatures for an extended
period of time. Keep the sensor in its protective packaging
until it is time for installation.

1. Position the sliding ultrasonic plate in the center apex of the

pipe, and scribe a mark on both sides of the ultrasonic plate.

2. Center the 12-inch mounting band, allowing the band to extend

about 4 inches beyond each side of the scribed location.

3. Conform one end of the curved band to the pipe configuration,

and spot drill to mark the bolt location.

4. Remove the curved band, drill an anchor bolt hole, and gently

tap a ¼-inch x 2 ¼-inch anchor bolt into the hole.

5. Mount the curved band to the anchor bolt through the pre-

drilled hole on the band, and hand-tighten a nut with washer to
the anchor bolt to secure the band.