FlowShark Models and Capabilities B-3

Model 5000-BG

(Dual Pipe, Wireless Modem)

Modbus ASCII (requires external power)

Modem - wireless

Power, external – available as an option running 12 volts at 1.2A

Power, internal – two 12-volt alkaline batteries – one for powering
monitor one for powering wireless modem

Sensors – two each - pressure, ultrasonic & velocity

Model 5000-BL

(Dual Pipe, Land Line Modem)

Modbus ASCII (Supported if external power is available.)

Modem - land line

Power, external - available as an option running 12 volts at 1.2A

Power, internal - two 12-volt alkaline batteries operating in parallel

Sensors - two each - pressure, ultrasonic & velocity

Model 5000-CG

(Single Pipe, 4-20 mA, Wireless Modem)

4-20mA input/output - supports two each

Modbus ASCII

Modem - wireless

Power, external (required) - running 12 volts at 1.2A

Rain Gauge (using I/O connector)

Sensors - one each - pressure, ultrasonic & velocity

Water Quality Sampler (using I/O connector)