rdcount_sync_mode

The  rdcount_sync_mode  parameter  defines  whether  the  read  counter  (rdcount)  output  is 
synchonous  to  the  rdclk  clock  input.  Assigning  a  value  of  1’b0  to  rdcount_sync_mode 
configures therdcount output to be synchonized to the wrclk clock. Assigning a value of 1’b1 
to  rdcount_sync_mode  configures  the  rdcount  output  to  be  synchonized  to  the  rdclk  clock. 
The default value of the rdcount_sync_mode parameter is 1’b1.

afull_offset

The  afull_offset  parameter  defines  the  word  depth  at  which  the  FIFO  almost_full  signal 
changes.  The  almost_full  flag  may  be  used  to  determine  the  number  of  blind  writes  to  the 
FIFO  that  can  be  made  without  monitoring  the  full  flag.    For  example,  if  the  afull_offset 
parameter is set to 17’h00004 and the almost_full flag is deasserted, the user is guaranteed that 
there are at least five empty locations in the FIFO. The user may write all five words without 
monitoring the full flag and be guaranteed that these words will be written to the FIFO and 
the write_err flag will not be asserted. The Maximum FIFO Depth is a function of the value 
assigned  to  the  read_width  parameter  as  shown  in 

Table  6‐19:  FIFO  read_width  versus 

Maximum Read Depth

.  The default value of the afull_offset parameter is 17’h00004, corre‐

sponding to five or less available locations remain in the FIFO.

Table 6-33: Condition to Assert almost_full Flag based on afull_offset Parameter Assignment

Mode

Condition when

almost_full flag is asserted

Condition when almost_full flag is

deasserted

sync_mode =
1’b0, fwft = 1’b0

afull_offset or fewer empty loca-
tions remain in the FIFO.

There are at least (afull_offset +1) empty
locations remaining in the FIFO.

sync_mode =
1’b0, fwft = 1’b1

afull_offset or fewer empty loca-
tions remain in the FIFO.

There are at least (afull_offset +1) empty
locations remaining in the FIFO.

sync_mode =
1’b1, fwft = 1’b0

afull_offset or fewer empty loca-
tions remain in the FIFO.

There are at least (afull_offset +1) empty
locations remaining in the FIFO.

sync_mode =
1’b1, fwft = 1’b1

Illegal parameter combination

Illegal parameter combination

aempty_offset

The  aempty_offset  parameter  defines  the  word  depth  at  which  the  FIFO  almost_empty 
changes. The almost_empty flag may be used to determine the number of blind reads from the 
FIFO  that  can  be  perfromed  without  monitoring  the  empty  flag.    For  example,  if  the 
aempty_offset parameter is set to 17’h0004 and the almost_empty flag is deasseted, the user is 
guaranteed that  there  are at least five words in the FIFO.  The user may  read  all five  words 
without monitoring the empty flag and be guaranteed that these words will be read from the 
FIFO  and the  read_err  flag  will  not  be asserted.   The FIFO  Depth  is a  function  of  the value 
assigned  to  the  read_width  parameter  as  shown  in 

Table  6‐19:  FIFO  read_width  versus 

Maximum Read Depth

.  The default value of the aempty_offset parameter is 17’h00004, corre‐

sponding to four or less words remaining in the FIFO.