Heading2 - fifo operational modes, Fifo operational modes – Achronix Speedster22i User Macro Guide User Manual

Page 184

Advertising
background image

Memories

LRAMFIFO

Speedster22i Macro Cell Library

Achronix Semiconductor Proprietary

PAGE 167

For example, the empty flag is computed from the Synchronized Write Pointer and the Read 
Pointer.    The  write  pointer  incurs  an  additional  delay  of  two  to  five  rdclk  cyles  (set  by  the 
wrptr_sync_stages  parameter)  before  it  is  used  to  calculate  the  empty  flag.    Therefore,  the 
empty flag will not transition from the empty to non‐empty state for a minimum of two rdclk 
cycles after the first write to the FIFO occurs.  A similar delay occurs for the almost_empty flag 
as well.  Likewise, for the full and almost_full flags, there are two to five wrclk cycles of delay 
in the actual FIFO status due to the synchronized read pointer.  For an asyncronous FIFO, the 
calculation of the flags does not immediately reflect the state of the FIFO.  While this behavior 
is normal for asynchronous FIFOs, it should be noted.   

Table 6‐60:  Empty and Almost Empty 

Flag Latency in Terms of Read Clock Cycles(ptr_sync_mode =1’b0)

 and 

Table 6‐61:  Full and 

Almost Full Flag Latency in Terms of Write Clock Cycles(ptr_sync_mode = 1’b0)

 show the 

latency for the FIFO flag calculations.

Table 6-60: Empty and Almost Empty Flag Latency in Terms of Read Clock Cycles

FIFO Status Flag

Read Clock Cycle Latency (rdclk cycles)

Flag Assertion

Flag Deassertion

empty flag

0

3 + rdptr_sync_stages

almost empty flag

0

3

(ptr_sync_mode =1’b0)

Table 6-61: Full and Almost Full Flag Latency in Terms of Write Clock Cycles

FIFO Status Flag

Write Clock Cycle Latency (wrclk cycles)

Flag Assertion

Flag Deassertion

full flag

0

3 + wrptr_sync_stages

almost full flag

0

3

(ptr_sync_mode = 1’b0)

Flag Latency in Synchronous Mode (ptr_sync_mode = 1’b1)

A synchronous FIFO has only a single clock, so there is no clock domain crossing required.  A 
synchronous FIFO has the advantage that the flag calculations are immediate and precise.

FIFO Operational Modes

The FIFO macro supports both single clock synchronous (same clock connected to wrclk and 
rdclk inputs without any phase offset between the two clocks) and dual clock asynchronous 
(two unrelated clocks or two related clocks) modes of operation.  For synchronous operation, 
both  the  wrclk  and  rdclk  inputs  must  be  connected  to  the  same  clock  net.    Phase  offsets 
between  the  two  clocks  in  synchronous  mode  is  not  allowed.    For  asynchronous  mode,  the 
user may connect the wrclk and rdclk inputs to two different clocks.  The FIFO will treat the 
two clocks as if they are unrelated.

Asychronous FIFO Mode (ptr_sync_mode = 1’b0)

After a reset operation, or after the last word has been read from the FIFO, the FIFO will be in 
an  empty  state  as  indicated  by  a  high  level  on  the  empty  flag.    When  the  FIFO  is  set  to 
asynchronous mode (ptr_sync_mode = 1’b0), the output of the FIFO remains unchanged after 
the first write to a FIFO in the empty state.  After the first write operation the empty flag will 
be deasserted indicating that there is data in the FIFO that may be read.  The user must read 
the FIFO by setting the rden high at which time the first word written into the FIFO will be 
available at the FIFO outputs at the next rising edge of the rdclk input.   Each subsequent read 
operation updates the FIFO outputs with the next stored data word if it is available (empty 
flag = false).