BRAM80KFIFO

Speedster22i Macro Cell Library

Achronix Semiconductor Proprietary

PAGE 133

Read and Write Count Outputs

Write Count Output

The  Write  Count  (wrcount)  output  of  the  FIFO  shows  the  value  of  the  Write  Pointer.  The 
wrcount  may  be  synchronized  to  either  the  wrclk  or  rdclk  clock  domains  by  setting  the 
wrcount_sync_mode  parameter  bit.    Setting  the  wrcount_sync_mode  parameter  to  1’b1 
outputs the wrcount directly from the Write Pointer (synchronous to the wrclk clock).  Setting 
the wrcount_sync_mode to 1’b0 outputs the wrcount synchronous to the rdclk output after it 
has  been  synchronized  to  the  rdclk  clock  through  a  synchonization  circuit  that  is 
wrptr_sync_stages  +  2  registers  deep.    Note  that  if  the  Write  Pointer  is  synchronized  to  the 
rdclk clock domain, the value of the Write Counter will be delayed and have a rate of change 
that  will  vary  dependent  on  the  rdclk  clock  rate. 

Figure  6‐10:  Write  Pointer  Synchronizer 

Block Diagram

 shows the Write Count Output Circuit.

Figure 6-10: Write Pointer Synchronizer Block Diagram

Read Count Output

The  Read  Count  (rdcount)  output  of  the  FIFO  shows  the  value  of  the  Read  Pointer.  The 
rdcount  may  be  synchronized  to  either  the  wrclk  or  rdclk  clock  domains  by  setting  the 
rdcount_sync_mode  parameter  bit.    Setting  the  rdcount_sync_mode  parameter  to  1’b1 
outputs the rdcount directly from the Read Pointer (synchronous to the rdclk clock).  Setting 
the  rdcount_sync_mode  parameter  to  1’b0  outputs  the  rdcount  synchronous  to  the  wrclk 
output after it has been synchronized to the wrclk clock through a synchonization circuit that 
is rdptr_sync_stages + 2 registers deep.  Note that if the Read Pointer is synchronized to the 
wrclk clock domain, the value of the Read Counter will be delayed and have a rate of change 
that  will  vary  dependent  on  the  wrclk  clock  rate.   

Figure  6‐11:  Read  Pointer  Synchronizer 

Block Diagram

 shows the Read Count Output Circuit.

Figure 6-11: Read Pointer Synchronizer Block Diagram

Write

Pointer

Write Pointer Synchronizer

d q

d q

d q

d q

d q

wrcount

wrclk

rdclk

wrcount_sync_mode

wrptr_sync_stages

Synchronized

Write Pointer
used for flag

00

01
10

11

0

1

calculations

Read

Pointer

Read Pointer Synchronizer

d q

d q

d q

d q

d q

rdcount

rdclk

wrclk

rdcount_sync_mode

rdptr_sync_stages

Synchronized

Read Pointer
used for flag

00

01
10

11

0

1

calculations