25 set igmp querier status, 26 set igmp querier tx-interval, 25set igmp querier status – Pilz PSSnet SHL 8T MRP User Manual

Page 141: 26set igmp querier tx-interval

Advertising
background image

PSSnet SHL - Command Line Interface

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

4.6 Device Configuration Commands

141

4.6.25 set igmp querier status

Configure the IGMP Snooping Querier's administrative status
(enable or disable).
Default

disable

Format

set igmp querier status {enable | disable}

Mode

Global Config

4.6.26 set igmp querier tx-interval

Configure the IGMP Snooping Querier's transmit interval. The range is 2 to
3599 seconds.
Default

125

Format

set igmp querier tx-interval <2-3599>

Mode

Global Config