PSSnet SHL - Command Line Interface

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

4.8 System Utilities

213

trap

Configures the sending of traps concerning the signal contact.
– enable enables sending traps,

– disable disables sending traps.

4.8.24 temperature

This command configures the lower and upper temperature limit for the
device. If these limits are exceeded, a trap is sent. The unit for the
temperature limit is °C (Celsius), the minimum value is -99, the maximum val-
ue is 99. The default for the lower limit is 0, for the upper limit, it is 70.
Note: to give the temperature in Fahrenheit, use the suffix f.
Format

temperature {lower-limit|upper-limit} <temperature
value> [{c|f}]

Mode

Global Config

lower-limit

Configure the lower temperature limit.

lower-upper

Configure the upper temperature limit.