23 signal-contact, 23signal-contact 212 – Pilz PSSnet SHL 8T MRP User Manual

Page 212

Advertising
background image

212

4.8 System Utilities

PSSnet SHL - Command Line Interface

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

4.8.23 signal-contact

This command configures the signal contacts.
Format

signal-contact {1|2|all}
{mode {auto|device-status|manual}
|monitor {aca-removal|all|
connection-error|hiper-ring|module-removal
|power-supply-1| power-supply-2
|power-supply-3-1|power-supply-3-2
|power-supply-4-1|power-supply-4-2
|ring-coupling|temperature} {disable|enable}
|state {closed|open}
|trap {disable|enable} }

Mode

Global Config

Contact No.

Selection of the signal contact:
– 1 signal contact 1,

– 2 signal contact 2,

– all signal contact 1 and signal contact 2.

mode

Selection of the operational mode:
– auto function monitoring,

– device-status the device-status determines the signal contact´s

status.
– manual manually setting the signal contact.

monitor

Enables or disables the monitoring of the selected event or all events.
– enable monitoring,

– disable no monitoring.

state

Set the manual setting of the signal contact:
– closed ,

– open.

Only takes immediate effect in manual mode.

Advertising