3 flow of operation, Flow of operation – Pilz PSSnet SHL 8T MRP User Manual

Page 36

Advertising
background image

Mode-based CLI

36

3.3 Flow of Operation

PSSnet SHL - Command Line Interface

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

3.3 Flow of Operation

This section captures the flow of operation for the CLI:

D

The operator logs into the CLI session and enters the User Exec mode.
In the User Exec mode the (Pilz Product)(exec)> prompt is displayed

on the screen.

The parsing process is initiated whenever the operator types a command and
presses <ENTER>. The command tree is searched for the command of in-
terest. If the command is not found, the output message indicates where the
offending entry begins. For instance, command node A has the command

"

show spanning-tree

"

but the operator attempts to execute the com-

mand

"

show arpp brief

"

then the output message would be

(Pilz Product)(exec)> show sspanning-tree^. (Pilz Prod-
uct)%Invalid input detected at '^' marker. If the operator has

given an invalid input parameter in the command, then the message conveys
to the operator an invalid input was detected. The layout of the output is de-
picted below:

(Pilz Product)(exec) #show sspanning-tree
^
(Pilz Product)Invalid input detected at '^' marker.

Fig. 2:

Syntax Error Message

After all the mandatory parameters are entered, any additional parameters
entered are treated as optional parameters. If any of the parameters are not
recognized a syntax error message will be displayed.

D

After the command is successfully parsed and validated, the control of
execution goes to the corresponding CLI callback function.

Advertising
This manual is related to the following products: