2 adept quattro internal connections, 3 xsys/xsystem connector – Adept s650HS Quattro User Manual

Page 119

Advertising
background image

Chapter 7: Technical Specifications

7.2 Adept Quattro Internal Connections

Quattro AIB/eAIB

Internal Connections

Quattro Panel
Connections

Force-Guided Relay
Cyclic Check
Control Circuit

Force-Guided

Force-Guided

Single-Phase
AC Input
200-240 VAC

High Power to
Amplifiers

Man 1

Man 2

Auto 1

Auto 2

XSLV-2 (XSYSTEM 8)

XSLV-3 (XSYSTEM 38)
XSLV-6 (XSYSTEM 14, 29)

XSLV-7 (XSYSTEM 30, 44)

ESTOPSRC

ESTOPGND

HPWRREQ

XSLV-9 (XSYSTEM 16)

XSLV-1 (XSYSTEM 17)

XSLV-5 (XSYSTEM 34)

To XSYS on
SmartController

Figure 7-10. Robot Internal Connections Diagram

7.3 XSYS/XSYSTEM Connector

Table 7-2. XSYS to XSYSTEM Connector Pinouts (eAIB only)

XSYS
Pin #

XSYSTEM

Pin #

Description

Comment

Pin Location

1

17

ESTOP_GND

E-Stop system Ground

2

8

ENABLE_SW_1-

3

38

ENABLE_SW_2-

4

15

HPWR_DIS

High Power Disable

5

34

HPWR_REQ

6

14 & 29

MUTE_GATE_1-

7

30 & 44

MUTE_GATE_2-

8

N/C

9

16

ESTOP_SRC

E-Stop System +24 V

Shell

Shell

SHIELD

Adept Quattro User's Guide, Rev F

Page 119 of 196