Chapter 8: maintenance - h, 1 periodic maintenance schedule – Adept s650HS Quattro User Manual

Page 131

Advertising
background image

Adept Quattro User's Guide, Rev F

Page 131 of 196

Chapter 8: Maintenance - H

NOTE: This chapter applies to the Adept Quattro H robots (non-USDA) only.

NOTE: Maintenance of user-added optional equipment is the user’s responsibility.
It is not covered in this manual.

8.1 Periodic Maintenance Schedule

Table 8-2 and Table 8-3 give a summary of the preventive maintenance procedures and
guidelines on frequency.

NOTE: The frequency of these procedures depends on the particular system, its
operating environment, and amount of usage. Use the times in the tables as
guidelines and modify the schedule as needed.

WARNING: The procedures and replacement of parts
mentioned in this section should be performed only by
skilled or instructed persons, as defined in the

Adept

Robot Safety Guide

.

The motor covers and the AIB/eAIB on the robot are not
interlocked—turn off and disconnect power if these have
to be removed. Lockout and tagout power before
servicing.

Table 8-1. Typical Cleaning Schedule, Non-raw Food

Item

Interval

Suggested Cleaning Action

Outer Arms and Ball
Studs

1 Week

Clean with wipes or water.

Platform

1 Week

Clean with wipes, air, or water.

Table 8-2. Suggested Inspection

Inspect/

Check

Sugg.

Interva-

l

Est.

Insp.

Time

Inspection

Suggested

Action

User Cabling

1 Week

15 Min

Inspect for wear around
robot joints and possible
binding on robot.

Replace cabling if
cracked or worn. Adjust
cable position if binding.