Chapter 9: Maintenance - HS

l

Teach Restrict Verification

This verifies that the hardware Teach Restrict is functioning correctly.

The initial utility screen will tell you which functions are commissioned. If a function is not
commissioned, its verification wizard will not be displayed. Any displayed verification wizard
can be run at any time, to ensure that its function is working properly.

Prerequisites

l

The robot must be set up and functional.

l

The robot must use eAIB amplifiers.

The AIB amplifiers do not support these hardware functions, and these wizards will not
run.

l

Adept ACE software must be installed.

l

The Front Panel keyswitch must be in Auto mode.

Figure 9-5. Adept Front Panel

l

No E-Stops can be activated.

l

For Configuration (E-Stop and Teach Restrict), the eAIB Commissioning Jumper must be
plugged into the XBELTIO jack on the eAIB.

NOTE: This is the only time that this jumper will be used. It is part number
11901-000, and must be removed for Verification and normal operation.