Adept s650HS Quattro User Manual

Page 50

Advertising
background image

Chapter 3: Robot Installation - HS

Procedure

1. Measure and mark all AIB/eAIB cables at 10 - 12 in. from the cable ends.

This amount of slack is needed to make the cable connections to the AIB/eAIB before the
cable inlet box is installed. See Figure 3-10.

Figure 3-5. Quattro HS Cable Inlet Box with Roxtec Frame

2. Adapt Roxtec modules to fit the cables that will be used. There should be a 0.1 to 1.0

mm gap between the halves of the modules for a proper seal. See the following figure.

Figure 3-6. Adapting a Module to the Cable Size, Checking the Gap

3. Grease the Roxtec modules, using Roxtec grease. See the following figure.

Adept Quattro User's Guide, Rev F

Page 50 of 196

Advertising
This manual is related to the following products: