Installing the Cable Inlet Box

1. Place the cable inlet box-AIB/eAIB gasket around the AIB/eAIB connection panel.

2. Attach the cable shield ground lug to the AIB/eAIB. The ground lug is for the cable

shield of the user-supplied 24 VDC cable. See Figure 3-11.

3. Hand-tighten all cables to the AIB/eAIB.

NOTE: All cables must be screwed into the AIB/eAIB.

The protective earth ground will be installed in the following steps.

4. Place the cable inlet box on the AIB/eAIB.

Ensure the gasket between the cable inlet box and the AIB/eAIB is in place.

5. Install three M4 bolts to secure the cable inlet box to the AIB/eAIB.

l

Do not yet install the bolt in the hole labeled as ground.

l

Use Loctite 222 in the bolt holes, not on the bolts themselves.

l

Use the bolts retained from removal.

l

Torque the bolts to 1.1 N·m (10 in-lb).

6. Install the M4 protective earth ground bolt, with toothed washer, through the cable inlet

box into the AIB/eAIB.

l

Ensure that the protective earth ground wire lug is under the toothed washer.

l

Use the bolt and toothed washer retained from removal.

l

No Loctite is needed for this bolt.

l

Torque the bolt to 1.1 N·m (10 in-lb).

7. Attach the cable inlet box back cover with four M4 bolts.

l

Use the bolts and washer seals retained from removal.

l

Use Loctite 222 in these bolt holes, not on the bolts themselves.

l

Torque bolts to 1.1 N·m (10 in-lb).

8. Install the cable tray.

Use the hardware and gasket retained during removal for securing the cable tray.

9.8 Replacing the AIB/eAIB Chassis

This section gives instructions on how to replace the AIB/eAIB chassis on an Adept Quattro