10 istatus values – Comtech EF Data NetVue Release 1.1 User Guide User Manual

Page 222

Advertising
background image

Advanced Configuration (System Display)

Revision 3

NetVue User Guide

MN-NETVUE

10–85

10.9.2.2.10 iStatus values

In the data and dataavg tables of a NetVue database, the iStatus field of a trending record gives
information about that particular record.

The iStatus field can have three positive values, and several negative values. Typically, the negative
values give information that is used to avoid an incorrect graphical representation of a Parameter’s trend
data when building trend graphs.

Value: 60
For average trending: The table entry contains average/max/min values calculated based on
Parameter values measured during the last 60 minutes.

Value: 5
For average trending: The table entry contains average/max/min values calculated based on
Parameter values measured during the last 5 minutes.

Value: 0
For real-time trending: The table entry contains normal real-time trend data without additional
information.

Value: -1
Element is starting up.

Value: -2
Element is being paused.

Value: -3
Element is being activated.

Value: -4
Element is going into a time-out state.

Value: -5
Element is coming out of a time-out state.

Value: -6
Element is being stopped.

Value: -7
A state and a display value were received, separated by a semi-colon. An example of such a display
value is No signal.

Value: -8
A normal value was received following -7.

Value: -9
Trending was started for the specified Parameter.

Value: -10
Trending was stopped for the specified Parameter