C o n f i g u r a t i o n

4-65

Set CAS Protocol

Type “1” or “2” on the AAL2/LES CAS Configuration menu to select
which CAS protocol to use.

Set CAS Refreshing

Rate

1

Type “R” on the AAL2/LES CAS Configuration menu to set the CAS
refresh rate.

2

Enter a zero (“0”) to disable CAS refresh, or enable CAS refresh by
entering a non-zero refresh rate value. The IAD displays the AAL2/LES
Manual Configuration menu.

3

Reset the IAD before enabling Idle CAS refresh.

Enable/Disable Idle

CAS Refreshing

1

Type “I” on the AAL2/LES CAS Configuration menu to enable or disable
idle CAS refreshing. You can only enable idle CAS refresh when CAS
refresh is enabled (immediately preceding).

2

Type “E” to enable Idle CAS refresh, or D to disable Idle CAS refresh. The
IAD displays the AAL2/LES Manual Configuration menu, and indicates in
the message section that the change in the Idle CAS refresh will take place
when the IAD is reset.

Change Maximum CPS-SDU Size; 45/64 Octets

Type “S” on the AAL2/LES Manual Configuration menu to switch the
maximum CPS payload size between 45 and 64 octets. The IAD displays the
AAL2/LES Manual Configuration menu. Included in the settings is a payload
size message indicating 45 or 64 octets.

Set “Combined Use” Timer

1

Type “T” on the AAL2/LES Manual Configuration menu to modify the
combined use timer (in 5 ms increments).

2

Type the new timer period and press Enter. The IAD updates the setting and
displays the menu.

Enable/Disable User State Control

Type “U” on the AAL2/LES Manual Configuration menu to enable or disable
user state control by toggling the state. The IAD displays the AAL2/LES
Manual Configuration menu. Included in the settings is a USC message
indicating that it is enabled or disabled.

Manual ATM Pace Control

Type “A” to set ATM Pace Control manually.