C o n f i g u r a t i o n

4-81

Set All Ports to Ground

Start

To set All Ports to Ground Start, follow the steps below.

1

Type “2” on the Start Mode Selection menu (Figure 4.95) to select Set All
Ports to Ground Start. The IAD sets all ports to Ground Start and saves the
configuration.

2

Press any key to return to the Start Mode Selection menu or press Escape to
continue with other voice path configuration.

3

Reset the IAD when you finish voice path configuration.

NOTICE:

For “Ground Start” applications all elements in the voice path must be
set to “Ground Start.”

Display Start Mode

To display Start Mode, follow the steps below.

1

To display a list of telephone ports and their current start mode, type “3” on
the Start Mode Selection menu (Figure 4.95). The IAD displays a list of
ports and the mode of each.

2

Press any key to return to the Start Mode Selection menu or press Escape to
continue with other voice path configuration.

Configure Individual

Port

To configure Start Mode on an individual port, follow the steps below.

1

Type “4” on the Start Mode Selection menu (Figure 4.95). For each port,
the IAD prompts you to type one of the following options for each port.

1—Loop Start

2—Ground Start

3—DID Wnk

4—E&M Wnk

5—RAW ABCD

0 or Enter—no change

2

After you have updated each port, Press Enter a final time. The IAD updates
the settings and saves the configuration.

3

Press any key to return to the Start Mode Selection menu or press Escape to
continue with other voice path configuration.

Set On Hook Transmission Mode of Ground Start Lines

To set On-Hook Transmission mode (OHT) (POTS only) for ground start
lines, follow the steps below.

1

Type “O” on the Voice Configuration menu (Figure 4.70) to display the
Ground Start OHT Mode Selection menu (Figure 4.96).