3 Utility Function Mode

3.2.30 Anti-Resonance Control Adjustment Function (Fn204)

3-80

• The tuning-less function must be disabled (Pn170.0 = 0).
• The test without a motor function must be disabled (Pn00C.0 = 0).
• The control must not be set to torque control.
• The write prohibited setting (Fn010) must not be set to write-protect parameters.

(2) Operating Procedure

With this function, an operation reference is sent, and the function is executed while
vibration is occurring.

The following methods can be used for the anti-resonance control adjustment func-
tion.

• Using Anti-Resonance Control for the First Time

• With Undetermined Vibration Frequency
• With Determined Vibration Frequency

• For Fine-tuning After Adjusting the Anti-Resonance Control

„

Using Anti-Resonance Control for the First Time

• With Undetermined Vibration Frequency

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main menu

for the utility function mode.
Use the

or

Key to move through

the list, select Fn204.

2

Press the

Key to display the initial set-

ting screen for tuning mode.

3

Press the

or

Key and set the tun-

ing mode “0.”