24 software reset (fn030), 1) preparation, 2) operating procedure – Yaskawa Sigma-5 User Manual: Operation of Digital Operator User Manual

Page 88

Advertising
background image

3 Utility Function Mode

3.2.24 Software Reset (Fn030)

3-54

3.2.24 Software Reset (Fn030)

This function enables resetting the SERVOPACK internally from software. This
function is used when resetting alarms and changing the settings of parameters that
normally require restarting the SERVOPACK. This function can be used to change
those parameters without restarting the SERVOPACK.

(1) Preparation

The following condition must be met to perform a software reset.

• The servomotor power must be OFF.

(2) Operating Procedure

Use the following procedure.

• Start software reset operation after the servomotor power

is OFF.

• This function resets the SERVOPACK independently of

host controller. The SERVOPACK carries out the same
processing as when the power supply is turned ON and
outputs the ALM signal. The status of other output signals
may be forcibly changed.

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main

menu for the utility function mode.
Use the

or

Key to move

through the list and select Fn030.

2

Press the

Key. The display changes

to the Fn030 execution display.

3

Press the

or

Key to select

“RESET5”.

B B

− F U N C T I O N −

F n 0 2 0 : S

− O r i g S e t

F n 0 3 0 : S o f t R e s e t

F n 0 8 0 : P o l e D e t e c t

F n 2 0 0 : T u n e L v l S e t

B B

S o f t w a r e R e s e t

R E S E T 1

B B

S o f t w a r e R e s e t

R E S E T 5

Advertising