3.2.14 Manual Offset-Signal Adjustment of the Motor Current Detection Signal (Fn00F)

3-34

3.2.14 Manual Offset-Signal Adjustment of the Motor Current

Detection Signal (Fn00F)

Use this function only if the torque ripple is still high after the automatic offset-signal
adjustment of the motor current detection signal (Fn00E).

Note: Fn005 cannot initialize any value adjusted with Fn00F.

(1) Preparation

The following condition must be met to manually adjust the offset of the motor cur-
rent detection signal.

• The write prohibited setting (Fn010) must not be set to write-protect parameters.

(2) Operating Procedure

Use the following procedure.

If this function is executed carelessly, it may worsen the char-
acteristics.
Observe the following precautions when performing manual
servo tuning.

• Run the servomotor at a speed of approximately

100 min

-1

.

• Adjust the offset while monitoring the torque reference with

the analog monitor until the ripple of torque reference
monitor's waveform is minimized.

• Adjust the phase-U and phase-V offset amounts alter-

nately several times until these offsets are well balanced.

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main

menu for the utility function mode.
Use the

or

Key to move

through the list and select Fn00F.

2

Press the

Key.

The display changes to the Fn00F exe-

cution display.

㧮㧮ޓޓޓޓޓ㧙㧲㨁㧺㧯㨀㧵㧻㧺㧙

㧲㨚㧜㧝㧞㧦㧿㨛㨒㨠ޓ㨂㨑㨞

㧲㨚㧜㧝㧝㧦㧹㨛㨠㨛㨞ޓ㧵㨚㨒㨛

㧲㨚㧜㧝㧜㧦㧼㨞㨙ޓ㧼㨞㨛㨠㨑㨏㨠

㧲㨚㧜㧜㧲㧦㧯㨡㨞ޓ㧹㨍㨚㨡㧭㨐㨖

㧮㧮
㧹㨍㨚㨡㨍㨘ޓ㧻㨒㨒㨟㨑㨠㧙㧭㧰㧶

㨆㧭㧰㧶㧵㨁㧩ޓ㧜㧜㧜㧜㧥

ޓ㨛㨒ޓ㧹㨛㨠㨛㨞ޓ㧯㨡㨞㨞㨑㨚㨠

㨆㧭㧰㧶㧵㨂㧩ޓ㧜㧜㧜㧜㧢