3.2 Operations

3-61

9

head1

3

Utility Function Mode

(2) Operating Procedure

Use the following procedure.

CAUTION

• When using the SERVOPACK with Jcalc = OFF (load moment of inertia is not cal-

culated), be sure to set a suitable value for the moment of inertia ratio (Pn103). If

the setting greatly differs from the actual moment of inertia ratio, normal control of

the SERVOPACK may not be possible, and vibration may result.

• When using the MP2000 Series with phase control, select the mode = 1 (standard

level). If 2 or 3 is selected, phase control of the MP2000 Series may not be possi-

ble.

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main

menu for the utility function mode.
Use the

or

Key to move

through the list, select Fn201.

2

Press the

Key to display the initial

setting screen for advanced autotuning.

3

Press the

, ,

or

Key and

set the items in steps 3-1 to 3-4.

3-1

„

Calculating Moment of Inertia

Select the mode to be used.

Usually, set Jcalc to ON.

Jcalc = ON: Moment of inertia calculated [Factory setting]

Jcalc = OFF: Moment of inertia not calculated

Note:

If the moment of inertia ratio is already known from the machine specifications, set the value in

Pn103 and set Jcalc to OFF.

3-2

„

Mode Selection

Select the mode.

Mode = 1: Makes adjustments considering responsiveness and stability (Standard level).

Mode = 2: Makes adjustments for positioning [Factory setting].

Mode = 3: Makes adjustments for positioning, giving priority to overshooting suppression.