4

Parameter Copy Mode

4.2 Operations

4-11

(2) Notes on Verify Parameters Function

• If an empty block (“

∗∗∗∗

”) is selected and the verify function is executed, the mes-

sage “No Data” is displayed, and the verification will not be executed. Press

the

Key to return to the parameter block selection display.

• Pressing the

Key to cancel the operation while verifying parameters. “Can-

celed” is displayed, and the display returns to the parameter block selection dis-
play.

• During verification operation, the executing process is displayed sequentially as

shown below. The verification takes about 10 seconds.

• If parameter matching is executed with a parameter block that differs from the

model of the SERVOPACK, the message “unmatched parameters” will appear and
matching will not be executed.

Operation cancelled

B B – V E R I F Y –

C a n c e l e d

0 0 :

∗ ∗ ∗ ∗

While reading the parameters from
the digital operator

Operation completed

In verification process

0 0 : S G D V – R 7 0

R e a d i n g

P a r a m e t e r s . .

< < O P > >

B B – V E R I F Y –

B B – V E R I F Y –

V e r i f y i n g

P a r a m e t e r s . .

0 0 : S G D V – R 7 0

< < O P – S E R V O > >

B B – V E R I F Y –

0 0 : S G D V – R 7 0

C o m p l e t e d