1) preparation, 2) operating procedure – Yaskawa Sigma-5 User Manual: Operation of Digital Operator User Manual

Page 41

Advertising
background image

3.2 Operations

3-7

9

head1

3

Utility Function Mode

(1) Preparation

There are no tasks that must be performed before displaying the alarm history.

(2) Operating Procedure

Use the following procedure.

Note: 1. If the same alarm occurs after more than one hour, the alarm will be saved. If it

occurs in less than one hour, it will not be saved.

2. The display “†.---” means no alarm occurs.
3. Delete the alarm history using the parameter Fn006. The alarm history is not cleared

on alarm reset or when the SERVOPACK main circuit power is turned OFF.

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main

menu for the utility function mode.
Use the

or

Key to move

through the list and select Fn000.

2

Press the

Key. The display changes

to the Fn000 execution display.

3

Press the

or

Key to scroll

through the alarm history. The alarm his-

tory can be viewed.

4

Press the

Key.

The display returns to the main menu of the

utility function mode.