Yaskawa Sigma-5 User Manual: Operation of Digital Operator User Manual

Page 97

Advertising
background image

3.2 Operations

3-63

9

head1

3

Utility Function Mode

6

Display example:

After the moment of inertia is calcu-

lated.

Calculates the moment of inertia.
Press the

Key if a positive (+) value

is set in STROKE (travel distance), or
press the

Key if a negative (-) value

is set. Calculation of the moment of inertia

will start. While the moment of inertia is

being calculated, the set value for Pn103

will flash and “ADJ” will flash instead of

“RUN.” When calculating the moment of

inertia is completed, the display will stop

flashing and the moment of inertia is dis-

played. The servomotor will remain ON,

but the auto run operation will be stopped

temporarily.

Notes:

• The wrong key for the set travel direc-

tion is pressed, the calculation will not

start.

• If the moment of inertia is not calculated

(Jcalc = OFF), the set value for Pn103

will be displayed.

• If “NO-OP” or “Error” is displayed dur-

ing operation, press the

Key to

cancel the function. Refer to (3) Failure

in Operation and take a corrective action

to enable operation.

7

After the servomotor is temporarily
stopped, press the

Key to save the

calculated moment of inertia ratio in the

SERVOPACK. “DONE” will flash for one

second, and “ADJ” will be displayed again.

Note: To end operation by calculating

only the moment of inertia ratio and
without adjusting the gain, press the

Key to end operation.

(cont’d)

Step

Display after Operation

Keys

Operation

㧭㧰㧶   㧭㨐㨢㨍㨚㨏㨑㨐  㧭㨀
㧼㨚㧝㧜㧟㧩㧜㧜㧟㧜㧜
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜
㧼㨚㧝㧠㧝㧩㧜㧜㧡㧜㧜

Advertising