3 Utility Function Mode

3.2.32 EasyFFT (Fn206)

3-92

2

Press the

Key. The display changes

to the Fn206 execution display.

Note: If the display is not switched and

“NO-OP” is displayed in the status

display, check to make sure that the

required operating conditions are

being met ((1) Preparation) and

take corrective action.

3

The cursor is on the setting of “Input.”
Press the

or

Key to set the

sweep torque reference amplitude (Pn456)

Setting range: 1 to 800.

Note: When making the initial settings for

EasyFFT, do not change the setting

for the reference amplitude. Start

with the original value of 15.

Increasing reference amplitude

increases the detection accuracy, but

the vibration and noise from the

machine will increase. Increase the

amplitude value little by little.

4

Press the

Key to turn the servomotor

power ON. The display “BB” and “Set-

ting” changes to “RUN” and “Ready.”

5

Press the

(forward run start) Key or

(reverse run start) Key to run the

servomotor and start the frequency mea-

surement. “Measure” is displayed during

the measurement.

Within a quarter turn, the servomotor will

move forward and then in reverse several

times.

Note:

• Press the

Key to cancel the mea-

surement. The servomotor stops moving

and the power turns OFF. The detection

of the resonance frequency is not com-

pleted.

• The actions of the servomotor are very

minute in this operation. Also at the

same time, the servomotor emits a noise.

To ensure safety, do not enter the work-

ing envelope of the motor.

(cont’d)

Step

Display after Operation

Keys

Operation