Parameter/Monitor Modes

2.1 Parameter Mode

2-3

∗ When the setting is modified, the parameters whose modified setting is validated only after

setting validation, the warning A.941 “Change of Parameters Requires the Setting Valida-

tion” is displayed. Turn the power OFF then ON to clear the warning and validate the new

setting.

4

Press the

Key to move the cur-

sor to the setting side (to the position of

the first digit of Pn000.0).

5

Press the

Key once to set “1”

for the first digit of Pn.000.0.

6

Press the

Key.

The new setting of Pn000 is written to

the SERVOPACK. The cursor moves to

the parameter number side and the

warning A.941 is displayed.

7

To enable the change in the setting, turn the power OFF and ON again.*

Step

Display after Operation

Keys

Operation

B B

− P R M / M O N −

P n 0 0 0 = n. 0 0 0 0

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 8 =

0

0 0 0 0 0 0 0 0 0 0

U n 0 0 D =

0

0 0 0 0 0 0 0 0 0 0

B B

− P R M / M O N −

P n 0 0 0 = n. 0 0 0 1

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 8 =

0

0 0 0 0 0 0 0 0 0 0

U n 0 0 D =

0

0 0 0 0 0 0 0 0 0 0

A . 9 4 1

− P R M / M O N −

P n 0 0 0 = n. 0 0 0 1

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 8 =

0

0 0 0 0 0 0 0 0 0 0

U n 0 0 D =

0

0 0 0 0 0 0 0 0 0 0