2 Parameter/Monitor Modes

2.2.2 Monitor Mode Display

2-10

2.2.2 Monitor Mode Display

• Operation Example

Select Un000 (Motor speed) on the first line, Un002 (Internal torque reference) on
the second line, Un005 (Input signal monitor) on the third line, and Un006 (Output
signal monitor) on the fourth line, and then save the display.

The following example shows when changing the displayed factory setting items.

B B

− P R M / M O N −

U n 0 0 0 =

0

0 0 0 0 0

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 5 =

U n 0 0 6 =

Motor speed

Internal torque reference

Input signal monitor

Output signal monitor

Step

Display after Operation

Keys

Operation

1

Press the

Key to select the

parameter/monitor mode.

2

Press the

Key once to move the

cursor to the fourth line.

3

or

Press the

or

Key to dis-

play Un006 (Output signal monitor).

4

Press the

Key once to move the

cursor to the line above.

B B

− P R M / M O N −

U n 0 0 0 =

0

0 0 0 0 0

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 8 =

0

0 0 0 0 0 0 0 0 0 0

U n 0 0 D =

0

0 0 0 0 0 0 0 0 0 0

B B

− P R M / M O N −

U n 0 0 0 =

0

0 0 0 0 0

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 8 =

0

0 0 0 0 0 0 0 0 0 0

U n 0 0 D =

0

0 0 0 0 0 0 0 0 0 0

B B

− P R M / M O N −

U n 0 0 0 =

0

0 0 0 0 0

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 8 =

0

0 0 0 0 0 0 0 0 0 0

U n 0 0 6 =

B B

− P R M / M O N −

U n 0 0 0 =

0

0 0 0 0 0

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 8 =

0

0 0 0 0 0 0 0 0 0 0

U n 0 0 6 =

Advertising