2) operating procedure – Yaskawa Sigma-5 User Manual: Operation of Digital Operator User Manual

Page 72

Advertising
background image

3 Utility Function Mode

3.2.15 Write Prohibited Setting (Fn010)

3-38

(2) Operating Procedure

Follow the steps to set enable or disable writing.

Note: To make the setting available, change the setting to P.0000 as shown in step 3.

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main

menu for the utility function mode.
Use the

or

Key to move

through the list and select Fn010.

2

Press the

Key. The display

changes to the Fn010 execution dis-

play.

3

Press the

or

Key to

select one of the following settings.

P.0000: Write permitted [Factory set-

ting]

P.0001: Write prohibited

4

Press the

Key. The setting value

is written into the SERVOPACK, and

the status display changes as follows:

“DONE” to “BB.”

Note: Saved settings will be enabled

after the SERVOPACK is

restarted.

5

Turn OFF the power and then turn it ON again to validate the new setting.

B B