3 Utility Function Mode

3.2.26 Tuning-less Levels Setting (Fn200)

3-58

3.2.26 Tuning-less Levels Setting (Fn200)

This function sets the load level during tuning-less function.

(1) Preparation

The following conditions must be met to perform the tuning-less function. If the set-
tings are not correct, “NO-OP” will be displayed during the tuning-less function.

• The tuning-less function must be enabled (Pn170.0 = 1).
• The write prohibited setting (Fn010) must not be set to write-protect parameters.
• The test without a motor function must be disabled. (Pn00C.0 = 0).

(2) Operating Procedure

Use the following procedure.

CAUTION

• To ensure safety, perform the tuning-less function in a state where the SERVO-

PACK can come to an emergency stop at any time.

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main

menu for the utility function mode.
Use the

or

Key to move

through the list, select Fn200.

2

Press the

Key to display the load

level of the tuning-less mode setting

screen.

Notes:

• If the response waveform causes over-

shooting or if the load moment of inertia

exceeds the allowable level (i.e., outside

the scope of product guarantee), press
the

Key and change the mode set-

ting to 2.

• If a high-frequency noise is heard, press

the

Key and change the mode set-

ting to 0.

3

Press the

Key to display the rigidity

level of the tuning-less mode setting

screen.