Operating Instructions Powador XP100-HV

P a r a m e t e r

Parameters

Units

Ranges

Descriptions

Default

FRT Asynchronous
Level

V

0 ~ 100

The voltage level in order to separate Asynchro-
nous and synchronous. Inverter will recognize as
Asynchronous if the diff erence between inverter
sensing output voltage and RMS value of positive
value is less then this parameter level

10

COSPHI (P/Pn) Ramp
Time

sec

0 ~ 99999

The slope setup value for PF’s answering time in
Cos(P/Pn)

10

COSPHI_1

-

-0.999 ~ -0.95 u
0.95 ~ 1

The variable power factor reference according to
active power P_1

1

P_1

%

0 ~ 100

The active power setup conference for COSPHI_1

0

COSPHI_2

-

-0.999 ~ -0.95 u
0.95 ~ 1

The variable power factor reference according to
active power P_2

1

P_2

%

0 ~ 100

The active power setup conference for COSPHI_2

50

COSPHI_3

-

-0.999 ~ -0.95 u
0.95 ~ 1

The variable power factor reference according to
active power P_3

1

P_3

%

0 ~ 100

The active power setup conference for COSPHI_3

50

COSPHI_4

-

-0.999 ~ -0.95 u
0.95 ~ 1

The variable power factor reference according to
active power P_4

1

P_4

%

0 ~ 100

The active power setup conference for COSPHI_4

50

COSPHI_5

-

-0.999 ~ -0.95 u
0.95 ~ 1

The variable power factor reference according to
active power P_5

1

P_5

%

0 ~ 100

The active power setup conference for COSPHI_5

50

COSPHI_6

-

-0.999 ~ -0.95 u
0.95 ~ 1

The variable power factor reference according to
active power P_6

1

P_6

%

0 ~ 100

The active power setup conference for COSPHI_6

50

COSPHI_7

-

-0.999 ~ -0.95 u
0.95 ~ 1

The variable power factor Reference according to
active power P_7

1

P_7

%

0 ~ 100

The active power setup conference for COSPHI_7

50

COSPHI_8

-

-0.999 ~ -0.95 u
0.95 ~ 1

The variable power factor reference according to
active power P_8

1

P_8

%

0 ~ 100

The active power setup conference for COSPHI_8

50

COSPHI_9

-

-0.999 ~ -0.95 u
0.95 ~ 1

The variable power factor reference according to
active power P_9

1

P_9

%

0 ~ 100

The active power setup conference for COSPHI_9

50

COSPHI_10

-

-0.999 ~ -0.95 u
0.95 ~ 1

The variable power factor Reference according to
active power P_10

1

P_10

%

0 ~ 100

The active power setup conference for COSPHI_10

100

Table 17: Controller Parameters