5 the 8ro and 8rosmt relay boards, 5 the 8ro and 8rosmt relay boards -9, Figure 2-11 – Emerson E2 User Manual

Page 33: Figure 2-12

Advertising
background image

I/O Network Boards and Peripherals

Hardware Overview

2

-

9

• CCB and CC-100 case controllers

The HHT does not require a separate power source.

The unit is powered from the RJ-11 connector on the
peripheral equipment. The HHT includes a standard male
RJ-11 to male RJ-11 cable.

2.2.5

The 8RO and 8ROSMT Relay

Boards

The 8RO (P/N 810-3005) board is a general-purpose

board used to connect an E2 to any of eight standard con-
trol relay outputs, but is now obsolete and has been
replaced by the 8ROSMT (P/N 810-3006) board.

To function, the 8RO board must be connected through

either the Echelon Network or the RS485 I/O Network to
the E2. When properly installed, the 8RO receives an elec-
trical impulse from the E2, which either opens or closes
any of eight contact relays. Output definitions within the
E2 allow the user to configure the 8RO board to interact

with any refrigeration system or environmental control
component.

The 8RO board is the direct link between the E2 and

component operation. Information gathered by the con-
troller from the input boards is checked against current
stored setpoints. If differences in the received input data
and the setpoint information are detected, a signal is either
sent to the proper 8RO relay, or an existing signal is dis-
continued. Through the use of this relay signal, control
functions that can be properly maintained by a simple con-
tact closure sequence are effectively operated by the E2.

The 8RO board is easily installed and operated within

the Retail Solutions Network environment because of its
straightforward design. Several of these features are
shown in Figure 2-11.

NOTE: The 9V battery and 9-12V DC adapter
connection are not used on this HHT model
(P/N 814-3110).

Figure 2-10

- Hand-held Terminal (814-3110)

LEGEND

Up Arrow - moves to previous screen,
editable field, or top of screen

1

3

4

11

7

8

9

10

2

The power switch determines if the HHT is
in self-powered mode (BATT), ext power (EXT),
or if powered from a target device (HOST)

1

4

3

2

RS-485 Connector

Enter - save into memory

5

6

7

8

10

9

11

12

13

14

LCD - four lines of 16 characters

Numeric keypad

F1 - Home Screen

External Power Connector (9-12 VDC)

Scrolls list selections and scrolls through
ASCII characters if in a text field

5

6

13

F2- Main Menu

Right Arrow - selects last editable field
starting from bottom of screen; selects
last editable field from bottom to top

Down Arrow - moves to next screen,
editable field, end of screen, or advances

Cancel - clears/erases text in editable field;
cancels overrides

12

14

Left Arrow - selects first editable field from
top of screen, and next editable field from
top to bottom

Figure 2-11

- 8RO Relay Output Board

Figure 2-12

- 8ROSMT Relay Output Board

Advertising