CHAPTER 7 8-BIT PWM TIMER

7.8

Notes on Using 8-bit PWM Timer

This section lists points to note when using the 8-bit PWM timer.

Notes on using 8-bit PWM timer

Error

Activating the counter by program is not synchronized with the start of counting-up using the selected

count clock. Therefore, the time from activating the counter until a match with the PWM compare register

(COMR) is detected may be shorter than the theoretical time by a maximum of one cycle count clock.

Figure 7.8-1 "Error on starting counter operation" shows the error that occurs on starting counter operation.

Figure 7.8-1 Error on starting counter operation

Notes on setting by program

Do not change the count clock cycle (CNTR: P1, P0) when the interval timer function or PWM timer

function is operating (CNTR: TPE = "1").

Stop the counter (CNTR: TPE = "0"), disable interrupts (TIE = "0") and clear the interrupt request flag

(TIR = "0") before switching between the interval timer function and PWM timer function (CNTR: P/

T).

Interrupt processing cannot return if the interrupt request flag bit (CNTR: TIR) is "1" and the interrupt

request enable bit is enabled (CNTR: TIE = "1"). Always clear the TIR bit.

The TIR bit is not set if the counter is disabled (TPE = "0") at the same time as the counter and COMR

register values match.

Counter value

Count clock

One cycle

Error

Cycle for 00

H

Counter activate

00

H

01

H

02

H

03

H

04

H