FUJITSU Semiconductor Controller MB89950/950A User Manual

Page 268

Advertising
background image

254

CHAPTER 12 LCD CONTROLLER/DRIVER

12.4.2

Output Waveforms during LCD Controller/Driver
Operation (1/3 Duty Ratio)

In the 1/3 duty ratio mode, the COM0, COM1 and COM2 outputs are used by the display.
COM3 is not used.

1/3 bias, 1/3 duty output waveform

The maximum potential difference exists between a segment output and the corresponding common output

when the segment (LCD cell) is turned on. Figure 12.4-4 "Output waveforms, 1/3 bias and 1/3 duty ratio

example" shows the output waveforms for the display RAM contents listed in Table 12.4-2 "Display RAM

contents example".

Table 12.4-2 Display RAM contents example

Segment

Display RAM contents

COM3

COM2

COM1

COM0

SEGn

1

0

0

SEGn+1

1

0

1

−: Not used