1 lcd controller/driver internal voltage divider – FUJITSU Semiconductor Controller MB89950/950A User Manual

Page 251

Advertising
background image

237

CHAPTER 12 LCD CONTROLLER/DRIVER

12.2.1

LCD Controller/Driver Internal Voltage Divider

LCD driver supply voltage can be taken from an internal voltage divider (external
voltage divider may also be used).

Internal voltage divider

In these devices, external voltage divider may also be connected at pins V1 through V3.

The selection of internal or external voltage divider is made by the drive supply voltage control bit of LCD

control register (LCDR: VSEL). VSEL = "1" connects the internal voltage divider. Set VSEL to "1" when

you want to use the internal voltage divider only (when no external voltage divider is connected).

The LCD enable is inactive when LCD operation is stopped (LCDR: MS1, MS0 = "00

B

"), or in stop mode

(STBC: STP = "1"). Pin V2 and V1 should be shorted together when using the 1/2 bias setting.

Figure 12.2-2 "Internal voltage divider equivalent circuit" shows an equivalent circuit of the internal

voltage divider.

Figure 12.2-2 Internal voltage divider equivalent circuit

V3

V2

V1

N-ch

P-ch

R

N-ch

P-ch

R

N-ch

P-ch

R

N-ch

V

2

V

1

V

3

VSEL

Short together when
using 1/2 bias.

MB89950/950A series

LCD enable

V

1

to V

3

: Voltages at V1 to V3 pins.