Example 3

To change the "PS" lock password, using the correct old password:
AT+CPWD=PS,1111,2222

(where 1111 = old "PS" password and 2222 =
new password)

To specify a new "PS" lock password, after the old password was disabled, e.g.
after three failed attempts to enter the password (only if Master Phone Code is
availbale):
AT+CPWD=PS,12345678,1111

(where 12345678 is the Master Phone code
and 1111 is the new password. You may also
use <newpwd> to restore the former disabled
password). This operation deactivates the
present phone lock and sets a new one. See
also Chapter 4.31.1.

Alternatively, whithout giving a new password:
AT+CPWD=PS,12345678

Deactivates the present phone lock.

4.35 AT+CR Service reporting control

Test command

AT+CR=?

Response

+CR: (list of supported

<mode>s) OK

Parameter

See write command

Read command

AT+CR?

Response

+CR: <mode> OK

Parameter

See write command

Write command

AT+CR=<mode>

Response

Configures the TA whether or not to transmit an intermediate result code +CR:
<serv>
to TE when a call is being set up.
OK

Parameter

<mode> 0 disable

1 enable

Intermediate result code

If enabled, an intermediate result code is transmitted at the point during con-
nect negotiation when the TA has determined the speed and quality of service
to be used, before any error control or data compression reports are transmit-
ted, and before any final result code (e.g. CONNECT) appears.
+CR:<serv

>

Parameter

<serv>

REL ASYNC

asynchronous non-transparent

Reference

GSM 07.07

Note

The PLMN influences the second air interface (to the terminator), therefore an-
other mode may be established from the network