AT Command Set

MC35_ATC_01_V03.02

Page 131 of 228

13.03.2002

5.8 AT+CMSS Send SMS message from storage

Test command

AT+CMSS=?

Response

OK

Parameter

Execute command

+CMSS=
<index>[,<da>
[,<toda>]]

Response

TA sends message with location value <index> from message storage
<mem2> to the network (SMS-SUBMIT or SMS-COMMAND). If new recipi-
ent address <da> is given for SMS-SUBMIT, it shall be used instead of the
one stored with the message. Reference value <mr> is returned to the TE
on successful message delivery. Values can be used to identify message
upon unsolicited delivery status report result code.

1) If text mode (+CMGF=1) and send successful:
+CMSS: <mr>[,scts>] OK

2) If PDU mode (+CMGF=0) and send successful:
+CMSS: <mr>[,ackpdu>] OK

3) If error is related to ME functionality:
+CMS ERROR: <err>

Parameter

<ackpdu>

GSM 03.40 RP-User-Data element of RP-ACK PDU;
format is same as for <pdu> in case of SMS, but without
GSM 04.11 SC address field and parameter shall be
bounded by double quote characters like a normal string
type parameter.

<index>

integer type; value in the range of location numbers sup-
ported by the associated memory

<da>

GSM 03.40 TP-Destination-Address Address-Value field
in string format; BCD numbers (or GSM default alphabet
characters) are converted into characters; type of ad-
dress given by <toda>

<scts>

GSM 03.40 TP-Service-Centre-Time-Stamp in time-
string format.

<toda>

GSM 04.11 TP-Destination-Address Type-of-Address
octet in integer format (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129)

<mr>

GSM 03.40 TP-Message-Reference in integer format

Reference

GSM 07.05