2.44 AT+ILRR Set TE-TA local rate reporting

Test command

AT+ILRR=?

Response

+ILRR:

(list of supported <value>s) OK

Parameter

See write command

Read command

AT+ILRR?

Response

+ILRR: <value> OK

Parameter

See write command

Write command

AT+ILRR=
<value>

The write command specifies whether or not an intermediate result code shall in-
dicate the currently used local rate when an incoming or outgoing data call is es-
tablished. The message is transmitted from the DCE (= TA) to the DTE (=TE) be-
fore the final result code of the connection setup (e.g. CONNECT) appears.

Response

OK

Parameter

<value> 0 Disables reporting of local port rate

1 Enables reporting of local port rate

Intermediate result code

+ILLR:<rate>

Parameter

<rate>

port rate setting in bit per second
0 (Autobauding, see Chapter 2.45.1)
300
600
1200
2400
4800
9600
19200
38400
57600
115200

Reference

V.25ter

Note

Example

ATD030112233445

+ILRR: 57600

CONNECT 9600/RLP