Siemens MC35 User Manual

Page 198

Advertising
background image

AT Command Set

MC35_ATC_01_V03.02

Page 198 of 228

13.03.2002

8.33 AT^SPLW Write an entry to the preferred operators list

Test command

AT^SPLW=?

Response

TA returns the whole index range supported by the SIM.
^SPLW

: (list of supported <index>s) OK

If error is related to ME functionality:
+CME ERROR: <err>

Parameter

See write command

Write command

AT^SPLW=
<index>
[,<oper>]

Parameter

TA writes an entry to the SIM list of preferred operators at location number <in-
dex>
. If <index> is given but <oper> is left out, the entry is deleted. If <oper> is
given but <index> is left out, <oper> is inserted in the next free location.

<index> location number
<oper>

string type; operator in numeric form; GSM location area identification
number
Note: <oper> is a 5 digit number, 3 digits country code and 2 digits for
the Network provider.

Response

OK
If error is related to ME functionality:
+CME ERROR: <err>

Reference

Siemens

Note

See also GSM 07.07: AT+CPOL