3.4 AT+FCIG Query or set the Local polling id

Test command

AT+FCIG =?

Response

(max. length of Local Polling ID string) (range of supported ASCII character val-

ues) OK

Parameter

See write command

Read command

AT+FCIG?

Response

<id> OK

Parameter

See write command

Write command

AT+FCIG =<id>

Response

OK

Parameter

<id>

Local Polling ID string, max. length and possible content as reported
by test command. Default value is empty string (“”).

Reference

EIA PN-2388

Note

See also “AT+FLID Query or set the Local Id setting capabilities”, pg. 48.
Used for Faxclass 2 only

3.5 AT+FCLASS Fax: Select, read or test service class

Test command

AT+FCLASS=?

See introduction to fax commands, pg. 40.
Response

(list of supported <n>s)
OK

Parameter

See write command

Read command

AT+FCLASS?

Response

<n> OK

Parameter

See write command

Write command

AT+FCLASS=
<n>

The ME is set to a particular mode of operation (data, fax). This causes the MA
to process information in a manner suitable for that type of information.

Response

OK

Parameter

<n>

0

data (e.g. EIA/TIA-602 or ITU V.25ter)

1

Fax class 1 (EIA/TIA-578-A, Service Class 1)

2

Fax class 2 (EIA/TIA SP-2388, an early draft version of
EIA/TIA-592-A – Service class 2.1)

Reference

EIA/TIA-592-A

Note

Using Error Correcting Mode (ECM) when sending FAXes over GSM should be
avoided.