AT Command Set

MC35_ATC_01_V03.02

Page 196 of 228

13.03.2002

at^spic

^SPIC: 1

OK

at+cpin=4713

+CME ERROR: incorrect password

at^spic

^SPIC: 63

OK

at+cpin=4714

+CME ERROR: incorrect password

at^spic

^SPIC: 63

8.31 AT^SPLM Read the PLMN list

Test command

AT^SPLM=?

Response

OK

Parameter

See execute command

Execute command

AT^SPLM

Response

TA returns the list of operator names from the ME. Each operator code <nu-
mericn>
that has an alphanumeric equivalent <alphan> in the ME memory is re-
turned.
^SPLM:

numeric <numeric1>,long alphanumeric <alpha1><CR><LF>

^SPLM:.....OK
If error is related to ME functionality:
+CME ERROR: <err>

Parameter

<numericn>

string type; operator in numeric form; GSM location area identifica-
tion number

<alphan>

string type; operator in long alphanumeric format; can contain up to
16 characters

Reference

Siemens

Note

See also GSM 07.07: +COPN, +COPS

Advertising