2.21 ATS3 Write command line termination character

Read command

ATS3?

Response

<n> OK

Write command

ATS3=<n>

This parameter setting determines the character recognized by TA to terminate
an incoming command line.

Response

OK

Parameter

<n>

000-013-127

command line termination character

Reference

V.25ter

Note

2.22 ATS4 Set response formatting character

Read command

ATS4?

Response

<n> OK

Write command

ATS4=<n>

This parameter setting determines the character generated by the TA for result
code and information text.

Response

OK

Parameter

<n>

000-010-127

response formatting character.

Reference

V.25ter

Note

2.23 ATS5 Write command line editing character

Read command

ATS5?

Response

<n> OK

Write command

ATS5=<n>

This parameter setting determines the character recognized by TA as a request
to delete the immediately preceding character from the command line.

Response

OK

Parameter

<n>

000-008-127

command line editing character

Reference

V.25ter

Note