8.3 AT^MONP Monitor neighbour cells

Test command

AT^MONP=?

Response

^MONP: (list of supported < period >s) OK

Write command

AT^MONP=[<period>]

This command can be used to retrieve information of up to six neighbour
cells automatically every n seconds. It is cancelled by any character sent
to the serial port except if autobauding is enabled (+IPR=0). Then type
character ´a´ to abort.

Response

See execute command

Parameter

<period>

1 – 254

Display period in seconds

Execute command

AT^MONP

This command can be used to obtain information of up to six neighbour
cells on request.

Response (Example)

Parameter:

Chann

Channel number

rs

RSSI value 0 – 63 (RSSI = Received signal strength indication)

dBm

Receiving level in dBm

PLMN

PLMN ID code

BCC

Base Station colour code

C1

coefficient for base station selection

C2

coefficient for base station selection

Reference

Siemens

Note

As a result of this command the requested output may be issued by the
ME at any moment (related to <period>

). To indicate such unsolicited re-

sult codes to a connected application, the ME usually activates it´s Ring
Line (Logic "0") for one second. This is not true for output of AT^MONI and
AT^MONP.