8.9 AT^SCTM Set critical operating temperature presentation mode or

query temperature

Use this command to monitor the temperature range of the module and the battery. The write com-
mand enables or disables the presentation of URCs to report critical temperature limits.
CAUTION: During the first 15 seconds after start-up, the module operates in an automatic report
mode: URCs can be always displayed regardless of the selected mode <n>.

Test command

AT^SCTM=?

Response

^SCTM:

(list of supported <n>s) OK

Parameter

See write command

Read command

AT^SCTM?

Response

TA returns the URC presentation mode and information about the current tem-
perature range of the module (not of the battery).
^SCTM: <n>, <m> OK

Parameters

<n>

0 Presentation of URCs is disabled (except for <m> equal to –2 or +2).
1 Presentation of URCs is enabled.

<m>

-2 Below lowest temperature limit (causes immediate switch-off)
-1 Below low temperature alert limit
0 Normal operating temperature

1 Above upper temperature alert limit

2 Above uppermost temperature limit (causes immediate switch-off)

Write command

AT^SCTM=<n>

Select <n> to enable or disable the presentation of the URCs. Please note that the
setting will not be stored upon Power Down, i.e. after restart or reset, the default
level 0 will be restored. To benefit from the URCs <n>=1 needs to be selected
every time you reboot the GSM engine.

Response

OK

Parameters

<n>

0

Suppress URCs (except for <m> equal to –2 or +2)

1

Enable presentation of URCs.

Please see notes below for further details.

Unsolicited result code

URCs will be automatically sent to the TA when the temperature reaches or ex-
ceeds the critical level, or when it is back to normal.

^SCTM_A: <m>

for battery (accumulator) temperature

^SCTM_B: <m>

for module (board) temperature