At+csns single numbering scheme, 41 at+csns single numbering scheme – Siemens MC35 User Manual

Page 112

Advertising
background image

AT Command Set

MC35_ATC_01_V03.02

Page 112 of 228

13.03.2002

4.41 AT+CSNS Single Numbering Scheme

The AT+CSNS command enables the ME to accept incoming calls when no bearer capability infor-
mation is provided with the call, e.g. single numbering scheme calls or calls originitating from analog
devices.
The command must be set before the call comes. By default, when you do not modify the settings,
all calls received without bearer element are assumed to be voice.
Please note that you can use the command if PIN authentication has been done during current ses-
sion. The setting will be automatically saved when you power down the GSM engine with AT^SMSO.

Test command

AT+CSNS=?

Response

+CSNS: (list of supported <mode>s)
OK

Read command

AT+CSNS?

Response

+CSNS: <mode>
OK

Write command

AT+CSNS=[<mode>]

Response

Write command
OK

Parameters

<mode>:

0

Voice

Each call received without bearer element is as-
sumed to be speech.

2

Fax

Each call received without bearer element is as-
sumed to be an incoming fax.

4

Data

Each call received without bearer element is as-
sumed to be a data call.
Please take into account that the bearer service
parameters set with AT+CBST apply to all data
calls including those received without bearer ca-
pability. To avoid conflicts see Chapter 4.5.

Reference

GSM 07.07

Note

Advertising