At+ftm transmit data, At+fts stop transmission and wait, 25 at+ftm transmit data – Siemens MC35 User Manual

Page 52: 26 at+fts stop transmission and wait

Advertising
background image

AT Command Set

MC35_ATC_01_V03.02

Page 52 of 228

13.03.2002

3.25 AT+FTM Transmit Data

Test command

AT+FTM=?

Response

(List of supported modulation modes)

OK

Parameter

See write command

Write command

AT+FTM=<mod>

This command causes the TA to transmit data using the modulation mode de-
fined below. An ERROR response code results if this command is issued while
the modem is on-hook.

Response

CONNECT
If error is related to ME functionality:
ERROR

Parameter

<mod>

modulation mode

96

V.29

9600 bps

72

V.29

7200 bps

48

V.27ter

4800 bps

24

V.27ter

2400 bps

Reference

TIA/EIA-578

Note

Used for Fax class 1 only

3.26 AT+FTS Stop Transmission and Wait

Write command

AT+FTS=<time>

This command causes the TA to terminate a transmission and wait for <time> 10
millisecond intervals before responding with the OK result code to the DTE.

Response

An ERROR response code results if this command is issued while the modem is
on-hook.

Parameter

<time>

0 – 85

no. of 10 millisecond intervals

Reference

TIA/EIA-578

Note

Used for Fax class 1 only

Advertising