2.27 ATS10 Set disconnect delay after indicating the absence of data carrier

Read command

ATS10?

Response

<n> OK

Write command

ATS10=<n>

This parameter setting determines the amount of time, that the TA remains con-
nected in absence of a data carrier. If the data carrier is detected before discon-
nect, the TA remains connected.
Response
OK

Parameter

<n>

001-002-254

number of tenths of seconds of delay

Reference

V.25ter

Note

2.28 ATS18 Extended error report

Test command

ATS18?

Response

<n> OK

Execute command

ATS18=<n>

TA returns an extended report of the reason for the last call release and location.

<n>

0 – 255, odd numbers set extended error report and even
numbers disable this feature.

Response

+Cause: <location ID>: <reason > OK

Parameter

<location ID>

Location ID as number code (see subclause 9.1.6.

<reason>

Reason for last call release as number code (see subclause
9.1.6).

Reference

Siemens

Note

This command works for data calls only. For voice calls please use AT+CEER.

2.29 ATT Select tone dialling

Execute command

ATT

Response

OK

Reference

V.25ter

Note

No effect for GSM