Cclk parameters -74 – PIONEERPOS AT Commands G24-LC User Manual

Page 138

Advertising
background image

Phone Books and Clock

3-74

G24-L AT Commands Reference Manual

April 15, 2008

The following table shows the +CCLK parameters.

Example

AT+CCLK=?

+CCLK: "88/12/31, 23:59:59, (-47-+48)"

OK

AT+CCLK="01/01/01, 01:01:01-08"

OK

AT+CCLK?

+CCLK: "01/01/01, 01:01:01-08"

OK

AT+CCLK="02/02/02, 02:02:02"

OK

Power cycling…

AT+CCLK?

+CCLK: "02/02/02, 02:02:02+00"

OK

AT+CCLK="03/03/03, 03:03:03+50"

+CME ERROR: Numeric parameter out of bounds

AT+CCLK

OK

AT+CCLK?

+CCLK: "05/10/27,16:52:31+08"

Power cycling…

AT+CCLK?

+CCLK: "05/10/27,16:52:50+08"

OK

Table 3-40: +CCLK Parameters

<Parameter>

Description

<time>

ASCII string of format:
yy/MM/dd,hh:mm:ss±zz
or
yy/MM/dd,hh:mm:ss
yy - 2-digit year [2000-2069]
MM - 2-digit month [01-12]
dd - 2-digit day of month [00-31]
hh - 2-digit hour [00-23]
mm - 2-digit minute [00-59]
ss - 2-digit seconds [00-59]
zz - (optional) time zone offset from GMT, in quarter-hours [-47...+48]. If this value is
not specified, the time zone offset will be 0.

Advertising
This manual is related to the following products: