Converting a Small System to a Branch Office

single-chassis Meridian 1 Option 11C Mini/Meridian 1 PBX 11C Chassis
with or without a chassis expander

single-cabinet CS 1000M Cabinet

single-cabinet CS 1000M Chassis with or without a chassis expander

Only single-cabinet and single-chassis systems (with or without a chassis
expander) can be converted. Multiple-cabinet and multiple-chassis Small
Systems must first be reduced to single cabinets or chassis.

To function as a Branch Office, the Small System must be equipped with
the following:

a system controller card that meets the requirements for CS 1000
Release 5.0 software, specifically:

— NTDK20HA or newer Media Gateway Card (MGC) equipped with an

NTTK25xx Software Daughterboard.

— NTDK97AB Mini System Controller (MSC) card for chassis systems

only. The NTDK97AB MSC card supports a maximum of 2000
Corporate Directory entries.

at least one Voice Gateway Media Card, running IP Line 4.5 software.
This card can be an 8- or 24-port Media Card (which occupies one slot)
or a 24-port ITG-P card (which occupies two slots).

a Signaling Server

— If a Signaling Server is added to a previously CISPR Class B system

(previously used in some specific countries), the system is now
compliant to Class A, as noted in the front and back pages of this
document.

Refer to Communication Server 1000E Upgrade - Option 11C Cabinet to CS
1000E (NN43041-464)
or Communication Server 1000E Upgrade - Option
11C Chassis to CS 1000E (NN43041-465)
for information on preparing a
Small System for conversion.

Conversion

A main office must exist before a Small System can be converted to a
Branch Office. The main office must be a CS 1000M or CS 1000E system
running CS 1000 Release 5.0 software.

If necessary, refer to CS 1000M and Meridian 1 Large System Upgrades
Overview (NN43021-458)
,Communication Server 1000E Upgrade - Option
11C Cabinet to CS 1000E (NN43041-464)
, or Communication Server 1000E
Upgrade - Option 11C Chassis to CS 1000E (NN43041-465)
for instructions