MG 1000B platform hardware installation

Do not modify or use the supplied AC power cord if it is not
the correct type. Refer to in Communication Server 1000S:
Installation and Configuration (NN43031-310)
for a detailed
power cord description.

b. Attach the female end of the power cord to the mating AC power

receptacle on the left side of the Signaling Server’s back panel.
See

Figure 82 "Back of Signaling Server" (page 235)

. Plug the

male end of the AC power cord into the AC power source (wall
outlet).

4

Connect a maintenance terminal to the Signaling Server.

a. Connect a DTE–DTE null modem serial cable (supplied with

the Signaling Server) from the back of the Signaling Server to a
maintenance terminal. The connection looks like that shown in

Figure 83 "Maintenance to Signaling Server connection" (page
236)

.

Figure 83
Maintenance to Signaling Server connection

b. The COM port on the maintenance terminal is set as follows:

Terminal type: VT100

Speed: 96 000

Data bits: 8

Parity: none

Stop bits: 1

Flow control: none

The Signaling Server is shipped with the Admin/Serial port set
to 19 200 Bit/s. Other available speeds are 38 400, and 115
200 Bit/s.

5

Power up the Signaling Server.

a. Open the bezel door (

Figure 84 "Signaling Server with open

bezel door" (page 237)

) to access the Power switch:

1. Grasp the tab at each end of the hinged bezel door.

Nortel Communication Server 1000

Branch Office Installation and Commissioning

NN43001-314

01.02

Standard

Release 5.0

20 June 2007